AC.32 Overpressure protector
The overpressure protector consists of a spring loaded piston valve.
Under normal pressure conditions the spring holds the valve open.
When the system pressure exceeds the set pressure, the force exerted by the spring is overcome and the valve closes.
The valve
will remain closed until the system pressure drops approx. 25 % below the
closing pressure, where-upon the force of the spring will open the valve.
Specification
Setting pressure
range |
0.4…2.5 bar 2…6 bar 5…25 bar 20…60 bar 50…250 bar 240…400 bar |
Connection |
PF
1/2” (F) x PF 1/2” (M) Others
on request |
Material |
Stainless steel |