EDN.820 Flush diaphragm
[EDN.820
series, Pressure Transmitters suitable for pressure measurement of food,
beverage, and viscous materials]
The
EDN.820 series pressure transmitters are designed and manufactured with a Flush
Diaphragm structure suitable for industrial processes using viscous fluids or
basic hygienic environments. All wetted parts are made of stainless steel,
providing excellent durability and corrosion resistance, while the housing and
body are made of aluminum materials commonly used in industrial applications. The
standard process connection is G1/2”, and various sealing options such as FKM,
EPDM, and Metal O-ring are available according to user requirements.
The
Piezoresistive Silicon Pressure Sensor applied to the EDN.820 series is
manufactured by combining highly precise modern electronic component
fabrication technology with advanced industrial PCB chip design. The electronic
components that amplify the signal from this sophisticated pressure sensor
undergo a variety of tests, including Noise, Burst, Insulation, and Surge
tests, to ensure reliable operation under diverse environmental conditions. The
product is designed to output an analog signal through strict process and
quality control. Each product is carefully calibrated during production and
undergoes 100% inspection before final shipment.
[Applications]
The
EDN.820 series is mainly used in the food and beverage industry, the
pharmaceutical industry, and general industries where pressure measurement of
viscous media is required.
■
Pharmaceutical and medical industries
■ Food and beverage industries
■ Water purification and wastewater treatment industries
■ Applicable for pressure measurement of viscous media
[Accuracy
Grades]
Depending
on user requirements, the EDN.820 series products offer the following accuracy
grades:
■
EDN.825 / Standard type: ±0.5% F.S
■ EDN.823 / High accuracy type: ±0.25% F.S
■ EDN.821 / Precision type: ±0.1% F.S
[Optional
Functions]
The
EDN.820 series provides contact signal and communication functions that users
can select as needed.
■
2-relay switches
■ RS 485
[General Technical
Specifications]
|
Pressure
ranges |
-1…0 bar
& 0…200 mbar to 0…250 bar |
|
Accuracy |
Standard: ± 0.5% F.S High accuracy: ± 0.25% Precision: ± 0.1% |
|
Electrical
connection |
Cable gland M12 plug |
|
Signal
output |
4...20 mA,
2 wire-system 0…10V, 3
wire-system 0…5V, 3
wire-system 1…5 V, 3
wire-system 0.5…4.5V,
3-wire system |
|
Operating
temperature |
-20…+80 ℃ / standard -40…+125℃ / option |
|
Options |
Relay 2 switches RS485 |